DC series is CONPHIL after years of laboratory experimentscombined with modern sophisticatedadvanced technology, developed from the high-tech materials, is adding dozens of polymer elements.DC series filter particles was "honeycomb" shape, cross-connected between each poreeach aperture um level and uniform in size as possible to increase the contact area of micro air molecules, the maximum Douzhu corrosive gashalf of each particle microporous catalyst containingsulfur-containing air can be hydrogenchlorine and other harmful gases in the adsorption and then released from the neutral non-corrosive gases when the catalyst after the reactionthe aperture will be released.

Modern industrial production, a large number of precision equipment using a new type of electronic components , ROHS directive is enforced in the world since then electronic components including circuit boards, chips and other production processes more using the " immersion silver " instead of toxic , corrosion-resistant and difficult to break down the "lead" , so , IT room, control room and other space environment also increased the use of extremely strict standards .
The main components of air are corrosive sulfur compounds , hydrides , chlorides and other dozens of extremely hazardous chemicals on IT precision equipment , chips, circuit boards and other obvious " creeping erosion " damage ; to H2S , for example, H2S as a weak acid , slightly soluble in water , can provide hydrogen ions HS- sulfur and sulfur ions S2-, based on the principle of electrochemical reaction , the copper substrate as the anode lose electrons to form copper ions Cu2 +, or copper ions Cu + curing, thereby forming a copper corrosion products . The water film to keep the hydrogen ion H + cathode ( silver ) aggregation consume electronic anode to form hydrogen molecules H2. Head larger molecular hydrogen in the metal is likely to cause stress damage, thus speeding up the corrosion process.
Surface artifacts vulnerable to invasion turbid ; humans have great harm.

DC-1000

Industrial rot can effectively removeIncluding hydrogen sulfide and erosion environmentSulfur dioxide and other acid gases.

DC-2000

Can efficiently remove various oxidizing gas pollutants.

DC-3000

With Conphil media company with the use of other chemicals, which can effectively remove a variety of gaseous pollutants.

Precision Environmental gaseous pollutantsDORAVILLE, GA – More than 25 years since its original publication, one of the most widely used2013-12-25

PM2.5-Most air pollution sourcesDORAVILLE, GA – More than 25 years since its original publication, one of the most widely used2013-10-08

Conphil-Data center particulate and gaseous pollutants GuideDORAVILLE, GA – More than 25 years since its original publication, one of the most widely used2012-12-05

Conphil- Precision Environmental SolutionsDORAVILLE, GA – More than 25 years since its original publication, one of the most widely used2011-12-22

ISA Standard 71.04 Changes Approved for the Protection of Today’s ElectronicDORAVILLE, GA – More than 25 years since its original publication, one of the most widely used1986-12-18